Sample Record for 2018-06-29-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213001 DEA: 032F0804 EFIS: 0300020462
QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB-20,70-0.5/R2.0,14.1/15.2
Work Description: UPGRADE SIDEWALKS, CURBS, DRIVEWAYS, SIGNS & SIGNALS TO ADA STANDARDS
Location Description: YUBA COUNTY IN MARYSVILLE AT VARIOUS LOCATIONS ON ROUTE 20 FROM I STREET TO BUCHANAN STREET AND ON ROUTE 70 FROM 1ST STREET TO 18TH STREET
Contractor Name: Dreambuilder Construction Corporation
Contractor Address: 1324 E LAWSON LANE, PLACENTIA CA 92870
Resident Engineer: Garrett Griffith Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2018-06-29-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/29/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/06/2018
The quantity of what the sample constitutes: 120
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Circle
Material Information
Rocap Number(s):
Heat Number(s): 428917
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s):
Bolt Specification: F1554
Bolt Length(s): 18"
Nut Specification: xxx
Washer Specification: xxx
Finish: HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 428917
Rocap Test Requirement(s):
Lubricant Requirements(s):
Test Results
Test 1 of 7
DIME Test ID: 2018-06-29-1-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 07/12/2018
Date Tested: 07/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: F 1554 Gr 55 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1A | F 1554 Gr 55 Rod | 0.334 | 31163 | 138 | 93302 | 72488 | 24211 | F 1554 Gr 55 Rod |
| |
UTM
|
400KIP
|
Temperature
|
72
|
Test 2 of 7
DIME Test ID: 2018-06-29-1-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/12/2018
Date Tested: 07/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
428917
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
.75 in
|
Bolt Length
|
18 in
|
Gage Type
|
Pass
|
Test 3 of 7
DIME Test ID: 2018-06-29-1-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/12/2018
Date Tested: 07/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
428917
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
.75 in
|
Bolt Length
|
18 in
|
Gage Type
|
Pass
|
Test 4 of 7
DIME Test ID: 2018-06-29-1-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/12/2018
Date Tested: 07/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
428917
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
.75 in
|
Bolt Length
|
18 in
|
Gage Type
|
Pass
|
Test 5 of 7
DIME Test ID: 2018-06-29-1-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/12/2018
Date Tested: 07/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
428917
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
.75 in
|
Bolt Length
|
18 in
|
Measurement Average
|
4.13 mils
|
Test 6 of 7
DIME Test ID: 2018-06-29-1-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/12/2018
Date Tested: 07/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
428917
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
.75 in
|
Bolt Length
|
18 in
|
Measurement Average
|
3.81 mils
|
Test 7 of 7
DIME Test ID: 2018-06-29-1-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/12/2018
Date Tested: 07/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
428917
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
.75 in
|
Bolt Length
|
18 in
|
Measurement Average
|