Sample Record for 2018-06-27-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 212741 DEA: 020E1804 EFIS: 0200000022
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-89-29.8/30.2
Work Description: BRIDGE REPLACEMENT
Location Description: PLUMAS COUNTY NEAR CANYON DAM FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF LAKE ALMANOR SPILLWAY
Contractor Name: Q&D CONSTRUCTION, INC.
Contractor Address: P.O Box 10865, Reno, NV 89510
Resident Engineer: Ryan Johnson Structure Rep.: Matt Crete
Sample Information
DIME Sample ID: 2018-06-27-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 06/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/06/2018
The quantity of what the sample constitutes: 60182 pounds
A brief description of the sample: Epoxy Coated Rebar
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fletcher Coating Co
Material Information
Rebar Heat Number(s): 4073764
Rebar Epoxy Batch Number(s): 8A26A173
Rebar Coating Specification: ASTM A934
Rebar Size (#): #10
Rebar Coating Color: Purple
Rebar Manufacturer: CMC,Gerdau,Nucor
Rebar Coater: Fletcher Coating Company
Rebar Powder Manufacturer: Unknown
Release Number: Unknown
Quality Assurance Code: Unknown
Test Results
Test 1 of 2
DIME Test ID: 2018-06-27-1-1
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/10/2018
Date Tested: 07/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
12 mils
|
Bar # for First Bar
|
10A
|
Bar # for Second Bar
|
10B
|
First Bar Mean
|
10.14
|
Second Bar Mean
|
10.07
|
Total mean value
|
10.11
|
Test 2 of 2
DIME Test ID: 2018-06-27-1-2
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Holiday Bend)
Verified Date: 07/10/2018
Date Tested: 07/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
2.6
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|