Print Report | Back to Sample Detail

Sample Record for 2018-06-20-19

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Shimmick/FCC/Impregilo (SFI) JV
Contractor Address: 11 Golden Shore, Suite 330, Long Beach, CA 90802
Resident Engineer: Structure Rep.: Sami Deeb

Sample Information

DIME Sample ID: 2018-06-20-19
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Independent Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/20/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/03/2018
The quantity of what the sample constitutes: 1 lot
A brief description of the sample: A490 Bolt assy
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LeJeune Bolt Company

Material Information

Rocap Number(s): L1412647
Heat Number(s): 10531190, 62143479, 262342
Nut Mfg. Lot Number(s): 27106-6214347903Z
Washer Mfg. Lot Number(s): D3644-114Z
Bolt Specification: A490
Bolt Length(s):
Nut Specification: A563 DH
Washer Specification: F436
Finish: Geomet
Diameter/Size: 1-1/4" x 4-1/4"
Bolt Mfg. Lot Number: 28201-10531190Z
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 8

DIME Test ID: 2018-06-20-19-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/02/2018
Date Tested: 07/20/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A490 Bolt
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
19A28201-10531190Z1-1/4\"158001702.86A490 BoltBrian
UTM 400KIP
Temperature no data

Test 2 of 8

DIME Test ID: 2018-06-20-19-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 08/02/2018
Date Tested: 07/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
19A27106-6214347903Z1?\"147637656.72Nut Proof LoadBrian
UTM 400KIP
Temperature 72 F

Test 3 of 8

DIME Test ID: 2018-06-20-19-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/02/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 19A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 28201-10531190Z
Finish Coating ASTM F1136 - Dachromet or Geomet
Product Markings A490 USA
Size 1.25 in
Bolt Length 4.25 in
Gage Type Pass

Test 4 of 8

DIME Test ID: 2018-06-20-19-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/02/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 19A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 27106-6214347903Z
Finish Coating ASTM F1136 - Dachromet or Geomet
Product Markings U DH3
Size 1.25 in
Gage Type NA

Test 5 of 8

DIME Test ID: 2018-06-20-19-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/02/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 19A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 28201-10531190Z
Finish Coating ASTM F1136 - Dachromet or Geomet
Product Markings A490 USA
Size 1.25 in
Bolt Length 4.25 in
Measurement Average 0.56 mils

Test 6 of 8

DIME Test ID: 2018-06-20-19-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/02/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 19A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 27106-6214347903Z
Finish Coating ASTM F1136 - Dachromet or Geomet
Product Markings U DH3
Size 1.25 in
Bolt Length no data in
Measurement Average 0.85 mils

Test 7 of 8

DIME Test ID: 2018-06-20-19-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/02/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 19A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number D3644-114Z
Finish Coating ASTM F1136 - Dachromet or Geomet
Product Markings P F436-3
Size 1.25 in
Bolt Length no data in
Measurement Average 0.42 mils

Test 8 of 8

DIME Test ID: 2018-06-20-19-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/02/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 19A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number D3644-114Z
Finish Coating ASTM F1136 - Dachromet or Geomet
Product Markings P F436-3
Size 1.25 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 40.45
Spacing Ok