Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
DEA: No Project
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2018-06-19-5
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/19/2018
Date that the sample was received by the laboratory/organization performing the testing: 06/26/2018
The quantity of what the sample constitutes: 49
A brief description of the sample: 1 1/2 x 36 anchor bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: A and M Nut and Bolt
Rocap Number(s): N/A
Heat Number(s): 3075024
Nut Mfg. Lot Number(s): DDYD
Washer Mfg. Lot Number(s): 306864
Bolt Specification: ASTM F1554 Gr. 55
Bolt Length(s): 36 inch
Nut Specification: ASTM A194 2H
ASTM A563 DH
Washer Specification: ASTM F436
Finish: HDG
Diameter/Size: 1.5 inch
Bolt Mfg. Lot Number: 42586-PPO
Rocap Test Requirement(s): None
Lubricant Requirements(s): None
DIME Test ID: 2018-06-19-5-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 07/03/2018
Date Tested: 06/28/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1A | DDYD | 1 1/2\" | 214010 | 951.98 | Proof Load | Fred |
| |
UTM
|
400KIP
|
Temperature
|
72 F
|
DIME Test ID: 2018-06-19-5-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
3075024
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
1.5 in
|
Bolt Length
|
36 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-06-19-5-3
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
1.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-06-19-5-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
1.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-06-19-5-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
3075024
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
1.5 in
|
Bolt Length
|
36 in
|
Measurement Average
|
5.26 mils
|
DIME Test ID: 2018-06-19-5-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
9.29 mils
|
DIME Test ID: 2018-06-19-5-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
8.79 mils
|
DIME Test ID: 2018-06-19-5-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
305538
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.14 mils
|
DIME Test ID: 2018-06-19-5-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
305538
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.24 mils
|
DIME Test ID: 2018-06-19-5-10
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
305538
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
34.8
|
Spacing
|
Ok
|
DIME Test ID: 2018-06-19-5-11
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
305538
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
33.7
|
Spacing
|
Ok
|
DIME Test ID: 2018-06-19-5-12
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 3075024 | 0.496 | 0.193 | 67137 | 92520 | 25.8 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2018-06-19-5-13
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 07/03/2018
Date Tested: 06/29/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 3075024 | 0.497 | 0.194 | 67721 | 93090 | 25.9 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|