Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2018-05-18-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 05/18/2018
Date that the sample was received by the laboratory/organization performing the testing: 05/18/2018
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Silica Fume
From where was the sample collected: Source
Laboratory sample identification: CM185825
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RED Industries
Brand: RED Industrial Products
Mill: Mississippi Silicon
Type of Cementitious Material: Silica Fume
DIME Test ID: 2018-05-18-1-2
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 01/23/2019
Date Tested: 08/13/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 Day Break. First cube out of spec range. Actual strength 5600 psi. 119% of control strength.
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
6139 psi
|
Compressive strength of 2nd specimen (psi)
|
5493 psi
|
Compressive strength of 3rd specimen (psi)
|
5702 psi
|
Average Compressive strength (to nearest 10 psi)
|
5780 psi
|
DIME Test ID: 2018-05-18-1-3
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 01/23/2019
Date Tested: 05/21/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Correction Factor (CF)
|
0.30
|
Corrected Residue (Rc)
|
25.35
|