Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 209695 DEA: 08347704 EFIS: 0800000616
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-SR-58-0/12.9
Work Description: (Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location Description: SR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Contractor Name: KIEWIT INFRASTRUCTURE WEST CO.
Contractor Address: 2215 E 1ST STREET, VANCOUVER, WA 98661
Resident Engineer: Shaine Shahidi Structure Rep.: Osama Abdalla
DIME Sample ID: 2018-05-02-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 05/02/2018
Date that the sample was received by the laboratory/organization performing the testing: 05/07/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: 2 Ductile Iron Casting
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI Farrar
Heat Number (s): C298
Part Number (s): 68 27 172
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar
Prestressing Manufacturer: DSI
DIME Test ID: 2018-05-02-2-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/10/2018
Date Tested: 05/09/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
2
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | C298 | 0.496 | 0.1932 | 63035 | 109680 | 8.4 | Brian | | C298 | 0.496 | 0.1932 | 63145 | 110630 | 8.9 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|