Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 020E0904 Cty SHA Rte 5 PM R29.3/R31.1,R45.0/R45.8 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Nathan Alexander |
Date Reported: |
05/01/2018 |
|
Address: |
TL Number: |
105220 |
||
City: |
||||
Project Name: REPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT |
||||
Prime Contractor: GOLDEN STATE BRIDGE, INC. |
||||
Sample Taken Date: |
04/24/2018 |
Mix Design: |
800-ULW-A |
|
Contractor: Unknown |
Location : IN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE. |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.97 | 27.99 | 167645 | 5989.5 | 1 |
2 | 5.97 | 27.99 | 165132 | 5899.7 | 1 |
DIME Test ID: 2018-04-24-10-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5940
Age of specimen: 7 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing