Sample Record for 2018-04-18-4
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 212647 DEA: 080Q6904 EFIS: 0800020426
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-330-40.6/43.5
Work Description: CULVERT REPAIR
Location Description: SAN BERNARDINO COUNTY NEAR RUNNING SPRINGS FROM 1.2 MILES SOUTH OF LIVE OAK DRIVE TO 0.6 MILE SOUTH OF ROUTE 18/330 SEPARATION
Contractor Name: UNITED ENGINEERING & CONSTRUCTION, INC
Contractor Address: 336 N Central Ave, Glendale, CA 91203
Resident Engineer: JONATHAN SKEITH Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2018-04-18-4
TL Number from the TL Form: 01
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/18/2018
Date that the sample was received by the laboratory/organization performing the testing: 04/20/2018
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 979-1
Structure unique identifier: CSP PIPE LINING FROM DS 01 TO DS 25 RTE 330
Structure name: Unknown
The fabricator/manufacturer/facility name: NOT PROVIDED
Material Information
The concrete mix design number: NOT PROVIDED
The truck number from where the sample was collected: NOT PROVIDED
The batch plant ticket number from where the sample was collected: NOT PROVIDED
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: NOT PROVIDED
A detailed description of where the material sample was collected: CSP PIPE LINING FROM DS 01 TO DS 25 RTE 330
Where the material sample would have been placed if not sampled: CSP PIPE LINING FROM DS 01 TO DS 25 RTE 330
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 3
DIME Test ID: 2018-04-18-4-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/26/2018
Date Tested: 04/25/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.02 in
|
Average diameter of cylinder 2
|
6.02 in
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
Compressive strength (to nearest 10 psi)
|
7360 psi
|
Maximum load on cylinder 1
|
204530 lb
|
Maximum load on cylinder 2
|
214660 lb
|
Compressive strength of cylinder 1
|
7186.6 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
7542.5 psi
|
Type of fracture pattern of cylinder 2
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data
|
Test 2 of 3
DIME Test ID: 2018-04-18-4-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/03/2018
Date Tested: 05/02/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.02 in
|
Average diameter of cylinder 2
|
6.02 in
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
Compressive strength (to nearest 10 psi)
|
7740 psi
|
Maximum load on cylinder 1
|
222570 lb
|
Maximum load on cylinder 2
|
218160 lb
|
Compressive strength of cylinder 1
|
7820.4 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
7665.5 psi
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
14 days
|
Age of specimen in hours
|
no data
|
Test 3 of 3
DIME Test ID: 2018-04-18-4-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/16/2018
Date Tested: 05/16/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
8780 psi
|
Maximum load on cylinder 1
|
250070 lb
|
Maximum load on cylinder 2
|
246230 lb
|
Compressive strength of cylinder 1
|
8845.8 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
8709.9 psi
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data
|