Print Report | Back to Sample Detail

Sample Record for 2018-02-20-32

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212852 DEA: 010H7604 QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-101-33.0/42.0
Work Description: Fire Damage Repairs: Roadway Repair, Drainage/Slope Repair, Erosion Control, Fencing, MBGR and Sign Replacement, Hazard Tree and Debris Removal.
Location Description:
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 1324 S. State Street, Ukiah, CA 95482
Resident Engineer: MUNES NASH Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-02-20-32
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT D01 - District 1 Materials Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 02/20/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/22/2018
The quantity of what the sample constitutes: jmf verification
A brief description of the sample: 0.5 HMA-A W/RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: granite Ukiah

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 6

DIME Test ID: 2018-02-20-32-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/13/2018
Date Tested: 04/13/2018
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.93 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 2 of 6

DIME Test ID: 2018-02-20-32-2
Test Method: AASHTO T329-13: Standard Method of Test for Moisture Content of Asphalt Mixtures by Oven Method (Moisture Content)
Verified Date: 04/13/2018
Date Tested: 04/13/2018
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Moisture Content 0.00 %
Percent Change 0 %

Test 3 of 6

DIME Test ID: 2018-02-20-32-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 04/13/2018
Date Tested: 04/13/2018
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2490.000
Bulk Specific Gravity 2 2.502
Bulk Specific Gravity 3 2.481
Average Bulk Specific Gravity 2.491

Test 4 of 6

DIME Test ID: 2018-02-20-32-4
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/13/2018
Date Tested: 04/13/2018
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.598
Theoretical maximum density at 25°C (77°F) no data

Test 5 of 6

DIME Test ID: 2018-02-20-32-5
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 04/13/2018
Date Tested: 04/13/2018
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 4.5 %
Percent Air Voids 2 3.7
Percent Air Voids 3 4.2
Percent Air Voids Average 4.1

Test 6 of 6

DIME Test ID: 2018-02-20-32-6
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 04/13/2018
Date Tested: 04/13/2018
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 102 psi
Average Wet Tensile Strength 93 psi
Tensile Strength Ratio 0.91