Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 07288604 Cty LA Rte 710 PM 6.0-9.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Unknown |
Date Reported: |
06/28/2018 |
|
Address: |
TL Number: |
L48-015-18 |
||
City: |
||||
Project Name: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
||||
Prime Contractor: Shimmick/FCC/Impregilo (SFI) JV |
||||
Sample Taken Date: |
04/05/2018 |
Mix Design: |
na |
|
Contractor: Unknown |
Location : Port of Long Beach (District 7) |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.37 | 6.01 | 7337.7 | 208170 | 2 |
2 | 28.46 | 6.02 | 7134.6 | 203050 | 2 |
DIME Test ID: 2018-04-05-4-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 7240
Age of specimen: 84 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing