Print Report | Back to Sample Detail

Sample Record for 2018-04-04-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212060 DEA: 010F5204 EFIS: 0116000016 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-R8.5/R22.4
Work Description: RUBBERIZED HMA OVERLAY
Location Description: HUMBOLDT COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF BENBOW OVERCROSSING TO FRENCH ROAD UNDERCROSSING
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: Unknown
Resident Engineer: Joaquin Rodriguez Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-04-04-3
TL Number from the TL Form: 865194
Sample Submitted By Organization: CT D01 - District 1 Materials Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/04/2018
Date that the sample was received by the laboratory/organization performing the testing: 04/05/2018
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1/2 RHMA-G
From where was the sample collected: Job Site
Laboratory sample identification: 61917
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser Plant A

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2018-04-04-3-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/05/2018
Date Tested: 04/05/2018
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: OBC 7.7% Target Values 7.3-8.2% Ton 539
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 7.62 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 2 of 2

DIME Test ID: 2018-04-04-3-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/05/2018
Date Tested: 04/05/2018
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: Ton 539
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.395
Theoretical maximum density at 25°C (77°F) no data