Print Report | Back to Sample Detail

Sample Record for 2018-03-28-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-03-28-8
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM2 - Type B Elastomeric Joint Seal
Sample Taken Date: 03/28/2018
Date that the sample was received by the laboratory/organization performing the testing: 03/30/2018
The quantity of what the sample constitutes: 1
A brief description of the sample: Joint Seal
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Watson Bowman

Material Information

Mfg. Lot Number(s): 0818178
Manufacturer(s): Watson Bowman
Temperature: 70
Humidity: 50
Comments: Unknown
Joint Seal Size: 3.75

Test Results

Test 1 of 7

DIME Test ID: 2018-03-28-8-1
Test Method: CTM 673-July 2012: Method of Determining Movement Rating of Type B1 and B2 Preformed Elastomeric Joint Seals
Verified Date: 04/26/2018
Date Tested: 04/03/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
UTM 11KIP
Temperature no data f
Humidity 50 %
Load at W1 55.1252 lbs
Width at 4 x Load at W1 1.55204 in
Nominal Width 3.75 in
Measured Maximum Uncompressed Width 3.93 in
Measured Minimum Uncompressed Width 3.803 in
Minimum Uncompressed Width as Specified by the Manufacturer (MUWASBM) 3.8 in
Height of Contact Face 3.692 in
Spec Minimum Uncompressed Width 3.8 in
Length no data
Area (5 Times of the Height of Contact Face) 18.46 sqin
Half of the Spec Minimum Uncompressed Width 1.9 in
85 Percent of the Spec Minimum Uncompressed Width 3.23 in
3 Times of the Area 55.38 sqin
4 Times of the Load at W1 220.501 in
W1 (US Units) 3.23 in
W1 (Metric Units) 82.042 millimeters
W2 (US Units) 1.552 in
W2 (Metric Units) 39.422 millimeters
Satisfactory of MR of (US Units) 1.678 in
Satisfactory of MR of (Metric Units) 42.62 millimeters
Optional W1 Measurement 1 3.2326 in
Optional W1 Measurement 2 55.7492 sqin

Test 2 of 7

DIME Test ID: 2018-03-28-8-2
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 04/26/2018
Date Tested: 04/04/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 70 f
Humidity 50 %
Reading #1 56
Reading #2 56
Reading #3 56
Reading #4 56
Reading #5 56
Mean 56

Test 3 of 7

DIME Test ID: 2018-03-28-8-3
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 04/26/2018
Date Tested: 04/04/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values psi
UTM 11KIP
Humidity 50 %
Temperature no data f
Sample 1 Median Thickness 0.076 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2357.9 lbf?in/in?
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.079 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2419.2 lbf?in/in?
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.075 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2372.3 lbf?in/in?
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2372.3 psi

Test 4 of 7

DIME Test ID: 2018-03-28-8-4
Test Method: ASTM D2628-91-re11-low: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (Low Temp Recovery)
Verified Date: 04/26/2018
Date Tested: 04/04/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 70 f
Humidity 50 %
Low Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face ) 3.75 in
Low Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face ) 3.409 in
Percent Recovery (Low Temp) 91 %

Test 5 of 7

DIME Test ID: 2018-03-28-8-5
Test Method: ASTM D2628-91-re11-high: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (High Temp Recovery)
Verified Date: 04/26/2018
Date Tested: 04/04/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 70 f
Humidity 50 %
High Temp Recovery (70 hrs at 212F) Size Before (Height of Contact Face ) 3.75 in
High Temp Recovery (70 hrs at 212F) Size After (Expanded Contact Face ) 3.766 in
Percent Recovery (High Temp) 100 %

Test 6 of 7

DIME Test ID: 2018-03-28-8-6
Test Method: ASTM D471-15a: Standard Test Method for Rubber Property - Effect of Liquids
Verified Date: 04/09/2018
Date Tested: 04/09/2018
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Oil Swell Percentage 40 %

Test 7 of 7

DIME Test ID: 2018-03-28-8-7
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 04/09/2018
Date Tested: 04/09/2018
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass