Print Report | Back to Sample Detail

Sample Record for 2018-03-19-14

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212795 DEA: 05937704 EFIS: 0514901244 Permit Numbers: 05176UB0132 QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-68-4.04
Work Description: Install a water pipeline bridge including a 36 inch diameter steel casing
Location Description: County of Monterey
Contractor Name: Garney Construction Company
Contractor Address: 1110 Airport Rd, Monterey, CA 93940
Resident Engineer: Ignacio Saavedra Structure Rep.: David Galarza

Sample Information

DIME Sample ID: 2018-03-19-14
TL Number from the TL Form: C836243
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 03/19/2018
Date that the sample was received by the laboratory/organization performing the testing: 03/26/2018
The quantity of what the sample constitutes: Two Threaded Rod Assemblies
A brief description of the sample: A722 HDG Threaded Bars
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coastal Fabrication

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type: Deformed
Rebar Size: 1.25"
Nut Specification for Threaded Bar: Unknown
System Manufacturer: Williams Form
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 62143718
Nut Heat Number(s): 8196752
Bar Lot Number: Unknown
Nut Lot Number: 32N9D
Coupler Heat Number(s): Unknown
Coupler Grade: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2018-03-19-14-1
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 03/28/2018
Date Tested: 03/28/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar & Nut A722
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
1A722 1.250\" Threaded Bar & Nut Heat #32N9DHeat #621437181.1791653411432126.532.3Bar & Nut A722Fred
Temperature 72 F
UTM 400KIP

Test 2 of 2

DIME Test ID: 2018-03-19-14-2
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 03/28/2018
Date Tested: 03/28/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar & Nut A722
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
2A722 1.250\" Threaded Bar & Nut Heat #32N9DHeat #621437181.2717192414100860Bar & Nut A722Fred
Temperature 72 F
UTM 400KIP