Print Report | Back to Sample Detail

Sample Record for 2018-03-21-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-03-21-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM2 - Type B Elastomeric Joint Seal
Sample Taken Date: 03/21/2018
Date that the sample was received by the laboratory/organization performing the testing: 03/22/2018
The quantity of what the sample constitutes: 1
A brief description of the sample: Joint Seal
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Watson Bowman

Material Information

Mfg. Lot Number(s): 0518173
Manufacturer(s): Watson Bowman
Temperature: 70
Humidity: 50
Comments: Unknown
Joint Seal Size: 3.75"

Test Results

Test 1 of 7

DIME Test ID: 2018-03-21-2-1
Test Method: CTM 673-July 2012: Method of Determining Movement Rating of Type B1 and B2 Preformed Elastomeric Joint Seals
Verified Date: 04/24/2018
Date Tested: 03/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
UTM 11KIP
Temperature 70 ?F
Humidity 50 %
Load at W1 56.2751 lbs
Width at 4 x Load at W1 1.55764 in
Nominal Width 3.75 in
Measured Maximum Uncompressed Width 3.964 in
Measured Minimum Uncompressed Width 3.877 in
Minimum Uncompressed Width as Specified by the Manufacturer (MUWASBM) 3.933 in
Height of Contact Face 3.74 in
Spec Minimum Uncompressed Width 3.877 in
Length no data
Area (5 Times of the Height of Contact Face) 18.7 sqin
Half of the Spec Minimum Uncompressed Width 1.9665 in
85 Percent of the Spec Minimum Uncompressed Width 3.29545 in
3 Times of the Area 56.1 sqin
4 Times of the Load at W1 225.1 in
W1 (US Units) 3.295 in
W1 (Metric Units) 83.704 millimeters
W2 (US Units) 1.558 in
W2 (Metric Units) 39.564 millimeters
Satisfactory of MR of (US Units) 1.738 in
Satisfactory of MR of (Metric Units) 44.14 millimeters
Optional W1 Measurement 1 3.2955 in
Optional W1 Measurement 2 56.474 sqin

Test 2 of 7

DIME Test ID: 2018-03-21-2-2
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 04/24/2018
Date Tested: 03/27/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 70 f
Humidity 50 %
Reading #1 57
Reading #2 56
Reading #3 57
Reading #4 57
Reading #5 57
Mean 56.8

Test 3 of 7

DIME Test ID: 2018-03-21-2-3
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 04/24/2018
Date Tested: 03/27/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values psi
UTM 11KIP
Humidity 50 %
Temperature 70 F
Sample 1 Median Thickness 0.071 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2775.3 lbf?in/in?
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.07 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2548.6 lbf?in/in?
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.077 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2404.1 lbf?in/in?
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2548.6 psi

Test 4 of 7

DIME Test ID: 2018-03-21-2-4
Test Method: ASTM D2628-91-re11-low: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (Low Temp Recovery)
Verified Date: 04/24/2018
Date Tested: 03/23/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 70 f
Humidity 50 %
Low Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face ) 3.75 in
Low Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face ) 3.384 in
Percent Recovery (Low Temp) 90 %

Test 5 of 7

DIME Test ID: 2018-03-21-2-5
Test Method: ASTM D2628-91-re11-high: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (High Temp Recovery)
Verified Date: 04/24/2018
Date Tested: 03/27/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 70 f
Humidity 50 %
High Temp Recovery (70 hrs at 212F) Size Before (Height of Contact Face ) 3.75 in
High Temp Recovery (70 hrs at 212F) Size After (Expanded Contact Face ) 3.701 in
Percent Recovery (High Temp) 99 %

Test 6 of 7

DIME Test ID: 2018-03-21-2-6
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 03/29/2018
Date Tested: 03/29/2018
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass

Test 7 of 7

DIME Test ID: 2018-03-21-2-7
Test Method: ASTM D471-15a: Standard Test Method for Rubber Property - Effect of Liquids
Verified Date: 03/29/2018
Date Tested: 03/29/2018
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Oil Swell Percentage 39 %