Project Information
Project ID: 210785 DEA: 07255104 EFIS: 0700000465
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60-R23.8/R24.5
Work Description: CONSTRUCT WESTBOUND ONRAMP AND CONCRETE PAVEMENT
Location Description: LA COUNTY, IN DIMOND BAR ANDINDUSTRY AT GRAND AVENUE/SR 57/60 IC
Contractor Name: POWELL CONSTRUCTORS, INC.
Contractor Address: 8555 Banana Ave, Fontana, CA 92335
Resident Engineer: Martin Sandoval Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2018-03-14-3
TL Number from the TL Form: 42863880
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 03/14/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/19/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: 6 X 12 CONCRETE CYLINDERS
From where was the sample collected: Job Site
Laboratory sample identification: 950-380
Structure unique identifier: RW 2
Structure name: RW 2
The fabricator/manufacturer/facility name: CEMEX
Material Information
The concrete mix design number: 1418590
The truck number from where the sample was collected: 10067800
The batch plant ticket number from where the sample was collected: 42863880
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: PLANT
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: RW 2 RW AND STEM
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 2
DIME Test ID: 2018-03-14-3-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/21/2018
Date Tested: 03/21/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
3080 psi
|
Maximum load on cylinder 1
|
87050 lb
|
Maximum load on cylinder 2
|
86940 lb
|
Compressive strength of cylinder 1
|
3079.2 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
3075.3 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data
|
Test 2 of 2
DIME Test ID: 2018-03-14-3-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/11/2018
Date Tested: 04/11/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.01 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Compressive strength (to nearest 10 psi)
|
4400 psi
|
Maximum load on cylinder 1
|
122380 lb
|
Maximum load on cylinder 2
|
126700 lb
|
Compressive strength of cylinder 1
|
4329.0 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
4466.0 psi
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data
|