Sample Record for 2018-03-13-9
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 212748 DEA: 081F2704 EFIS: 0814000195
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-210-R29.3/R33.0
Work Description: TREAT DECK, REPLACE JOINT SEALS AND ELASTOMERIC BEARING PADS
Location Description: SAN BERNARDINO COUNTY IN REDLANDS AND HIGHLAND AT VARIOUS LOCATIONS FROM BASELINE ROAD TO ROUTE 210/10 SEPARATION
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606
Resident Engineer: Ezz Gayed Structure Rep.: Ching Chuang
Sample Information
DIME Sample ID: 2018-03-13-9
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 03/13/2018
Date that the sample was received by the laboratory/organization performing the testing: 03/15/2018
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 16487-1
Material/Compound/Elastomer ID: Unknown
Samples Representing: 7
Description (size): 3.5"x20"x22"
Comments: Unknown
Description (Number of Shims): 7
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: Unknown
Test Results
Test 1 of 4
DIME Test ID: 2018-03-13-9-1
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 03/26/2018
Date Tested: 03/19/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2KIP
|
Humidity
|
50 %
|
Temperature
|
70 F
|
Sample 1 Median Thickness
|
0.07 in
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2571.4 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.075 in
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2446.8 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.076 in
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2578.9 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2571.4 lbf/in^2
|
Test 2 of 4
DIME Test ID: 2018-03-13-9-2
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 03/26/2018
Date Tested: 03/19/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
no data
|
Humidity
|
50 %
|
Temperature
|
70 F
|
Sample 1 Median Thickness
|
0.074 in
|
Sample 1 Tear Strength
|
216.2 lbf / in
|
Sample 2 Median Thickness
|
0.069 in
|
Sample 2 Tear Strength
|
231.9 lbf / in
|
Sample 3 Median Thickness
|
0.069 in
|
Sample 3 Tear Strength
|
202.9 lbf / in
|
Median of the Tear Strength Values
|
216.2 lb/in
|
Test 3 of 4
DIME Test ID: 2018-03-13-9-3
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 03/26/2018
Date Tested: 03/19/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
70 f
|
Humidity
|
50 %
|
Reading #1
|
52
|
Reading #2
|
52
|
Reading #3
|
52
|
Reading #4
|
52
|
Reading #5
|
52
|
Mean
|
52
|
Test 4 of 4
DIME Test ID: 2018-03-13-9-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 03/26/2018
Date Tested: 03/23/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: