Print Report | Back to Sample Detail

Sample Record for 2018-03-01-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-R37.4 - R46.5
Work Description: (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location Description: IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
Contractor Name: Flatiron-Skanska-Stacy and Witbeck, a Joint Venture
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: Steve McMillan Structure Rep.: Phong Le

Sample Information

DIME Sample ID: 2018-03-01-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Retest
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 03/01/2018
Date that the sample was received by the laboratory/organization performing the testing: 03/05/2018
The quantity of what the sample constitutes: 125 pcs.
A brief description of the sample: No. 8 grade 075 epoxy coated thread bar
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Eng

Material Information

Production or Authorization Testing: Retest
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type:
Rebar Size: 8
Nut Specification for Threaded Bar: N/A
System Manufacturer: Williams Form Eng
Epoxy Coating Color: Purple
Threaded Bar Application: Soil Nail
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 100790536
Nut Heat Number(s): N/A
Bar Lot Number: N/A
Nut Lot Number: N/A
Coupler Heat Number(s): N/A
Coupler Grade: N/A

Test Results

Test 1 of 2

DIME Test ID: 2018-03-01-1-1
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 03/06/2018
Date Tested: 03/06/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 10
Upper spec. limit USL 15
Bar # for First Bar 1
Bar # for Second Bar 2
First Bar Mean 10.91
Second Bar Mean 11.8
Total mean value 11.35

Test 2 of 2

DIME Test ID: 2018-03-01-1-2
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 03/06/2018
Date Tested: 03/06/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 10
Upper spec. limit USL 15
Bar # for First Bar 3
Bar # for Second Bar 4
First Bar Mean 17.47
Second Bar Mean 12.04
Total mean value 14.75

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To