Project Information

Project ID: 211819 DEA: 080G7704 EFIS: 0814000175 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-0.00/41.80
Work Description: INSTALL TMS FIELD ELEMENTS
Location Description: RIVERSIDE COUNTY FROM SAN DIEGO COUNTY LINE TO 1.0 MILE NORTH OF ROUTE 15 / 91 SEPARATION
Contractor Name: DYNALECTRIC
Contractor Address: 4462 Corporate Center Dr., Los Alamitos, CA 90720
Resident Engineer: Inderjeet Harika Structure Rep.: Vega, Arnel

Sample Information

DIME Sample ID: 2018-02-12-3
TL Number from the TL Form: 20180212
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 02/12/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/14/2018
The quantity of what the sample constitutes: 4
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 973-212
Structure unique identifier: STA F 1069 30
Structure name: Unknown
The fabricator/manufacturer/facility name: ROBERTSONS

Material Information

The concrete mix design number: SC590B38
The truck number from where the sample was collected: 1946
The batch plant ticket number from where the sample was collected: 3370914
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TAIL
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2018-02-12-3-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/20/2018
Date Tested: 02/20/2018
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.02 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.46 in^2
Compressive strength (to nearest 10 psi) 2480 psi
Maximum load on cylinder 1 69670 lb
Maximum load on cylinder 2 71440 lb
Compressive strength of cylinder 1 2448.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 2510.2 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 8 days
Age of specimen in hours no data

Test 2 of 2

DIME Test ID: 2018-02-12-3-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/12/2018
Date Tested: 03/12/2018
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 6.02 in
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.46 in^2
Compressive strength (to nearest 10 psi) 4130 psi
Maximum load on cylinder 1 119780 lb
Maximum load on cylinder 2 115070 lb
Compressive strength of cylinder 1 4222.1 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 4043.2 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data