Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
DEA: No Project
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2018-02-16-4
TL Number from the TL Form:
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/16/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/23/2018
The quantity of what the sample constitutes: 48
A brief description of the sample: Anchor Bolt Assembly
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AM Nut and Bolt
Rocap Number(s):
Heat Number(s): 3075024, 177736, 162495
Nut Mfg. Lot Number(s): DDYD
Washer Mfg. Lot Number(s): 302113
Bolt Specification: F1554
Bolt Length(s): 42"
Nut Specification: A194
Washer Specification: F436
Finish: HDG
Diameter/Size: 1 1/2"
Bolt Mfg. Lot Number: 3075024
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2018-02-16-4-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 03/01/2018
Date Tested: 02/27/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: Nut Proof
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 4A | DDYD | 1 1/2\" | 213660 | 950.41 | Nut Proof | Brian |
| |
UTM
|
400KIP
|
Temperature
|
72 F
|
DIME Test ID: 2018-02-16-4-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 03/01/2018
Date Tested: 02/28/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 3075024 | 0.501 | 0.197 | 64407 | 91480 | 26.7 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2018-02-16-4-3
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 03/01/2018
Date Tested: 02/28/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 3075024 | 0.501 | 0.197 | 64653 | 91540 | 26.6 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2018-02-16-4-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3075024
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
1.5 in
|
Bolt Length
|
42 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-02-16-4-5
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H/DH D/N
|
Size
|
1.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-02-16-4-6
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H/DH D/N
|
Size
|
1.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-02-16-4-7
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H/DH D/N
|
Size
|
1.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-02-16-4-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3075024
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
1.5 in
|
Bolt Length
|
42 in
|
Measurement Average
|
5.63 mils
|
DIME Test ID: 2018-02-16-4-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H/DH D/N
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.01 mils
|
DIME Test ID: 2018-02-16-4-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H/DH D/N
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.79 mils
|
DIME Test ID: 2018-02-16-4-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYD
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H/DH D/N
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.21 mils
|
DIME Test ID: 2018-02-16-4-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
302113
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.59 mils
|
DIME Test ID: 2018-02-16-4-13
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
302113
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.18 mils
|
DIME Test ID: 2018-02-16-4-14
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
302113
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
34.75
|
Spacing
|
Ok
|
DIME Test ID: 2018-02-16-4-15
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/01/2018
Date Tested: 03/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
302113
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
35.25
|
Spacing
|
Ok
|