Sample Record for 2018-02-03-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 210915 DEA: 07306404 EFIS: 0714000165
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R24.7/R44.9
Work Description: INSTALL CHANGE MESSAGE SIGNS AND TRAFFIC MONITORING STATIONS
Location Description: IN LOS ANGELES COUNTY, IN VARIOUS CITIES ALONG I-210 CORRIDOR,BETWEEN SR-134 & SR-57
Contractor Name: SELECT ELECTRIC, INC.
Contractor Address: 13250 Kirkham Way, Poway, CA 92064
Resident Engineer: Warren Yue Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2018-02-03-1
TL Number from the TL Form: CMS1FNDTN
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 02/03/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/05/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 971-TN
Structure unique identifier: 210 EB AT ALLEN AVE
Structure name: Unknown
The fabricator/manufacturer/facility name: ROBERTSONS
Material Information
The concrete mix design number: SM450P47
The truck number from where the sample was collected: 1643
The batch plant ticket number from where the sample was collected: 3290165
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 1
DIME Test ID: 2018-02-03-1-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/05/2018
Date Tested: 03/03/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.01 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Compressive strength (to nearest 10 psi)
|
5840 psi
|
Maximum load on cylinder 1
|
163400 lb
|
Maximum load on cylinder 2
|
167230 lb
|
Compressive strength of cylinder 1
|
5780.0 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
5894.6 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data
|