Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212795 DEA: 05937704 EFIS: 0514901244 Permit Numbers: 05176UB0132
QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-68-4.04
Work Description: Install a water pipeline bridge including a 36 inch diameter steel casing
Location Description: County of Monterey
Contractor Name: Garney Construction Company
Contractor Address: 1110 Airport Rd, Monterey, CA 93940
Resident Engineer: Ignacio Saavedra Structure Rep.: David Galarza
DIME Sample ID: 2018-01-29-6
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 01/29/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/02/2018
The quantity of what the sample constitutes: 1
A brief description of the sample: Elastomeric Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification: 16202-1, 16202-2
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Mfg. Lot Number(s): 16202-1, 16202-2
Material/Compound/Elastomer ID: 2 527
Samples Representing: 16202 1
Description (size): 3 x 10 x 14
Comments: Unknown
Description (Number of Shims): 6
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: Unknown
DIME Test ID: 2018-01-29-6-1
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 02/08/2018
Date Tested: 02/08/2018
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2018-01-29-6-4
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 02/21/2018
Date Tested: 02/08/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
no data
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.075 in
|
Sample 1 Tear Strength
|
200 lbf / in
|
Sample 2 Median Thickness
|
0.08 in
|
Sample 2 Tear Strength
|
200 lbf / in
|
Sample 3 Median Thickness
|
0.088 in
|
Sample 3 Tear Strength
|
215.9 lbf / in
|
Median of the Tear Strength Values
|
200 lb/in
|
DIME Test ID: 2018-01-29-6-5
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 02/21/2018
Date Tested: 02/09/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
5
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2KIP
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.069 in
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2254.3 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.067 in
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2202.4 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.067 in
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2261.9 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Sample 4 Median Thickness
|
0.065 in
|
Sample 4 Thickness all Within 0.003 inch?
|
Yes
|
Sample 4 Ultimate Tensile
|
2331.3 lbf/in^2
|
Sample 4 Elongation (350% Min)
|
Pass
|
Sample 5 Median Thickness
|
0.067 in
|
Sample 5 Thickness all Within 0.003 inch?
|
Yes
|
Sample 5 Ultimate Tensile
|
2440.5 lbf/in^2
|
Sample 5 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2261.9 lbf/in^2
|
DIME Test ID: 2018-01-29-6-6
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 02/21/2018
Date Tested: 02/07/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
51
|
Reading #2
|
50
|
Reading #3
|
51
|
Reading #4
|
51
|
Reading #5
|
52
|
Mean
|
51
|