Sample Record for 2018-01-24-8
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209139 DEA: 071170U4 EFIS: 0700000085
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-33.2/37.2
Work Description: CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location Description: LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE WEST OF PUENTE AVENUE UNDERCROSSING TO 0.2 MILE EAST OF HOLLENBECK STREET UNDERCROSSING
Contractor Name: Ames Construction, inc.
Contractor Address: 391 N Main Street, Suite 302, Corona, Ca 92880
Resident Engineer: Raj Punjabi Structure Rep.: Cardiel Bugarin
Sample Information
DIME Sample ID: 2018-01-24-8
TL Number from the TL Form: 101119199
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/24/2018
Date that the sample was received by the laboratory/organization performing the testing: 01/26/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 882-99
Structure unique identifier: VINCENT AVE UC WIDEN ABUT 1L AND 2L PAVINF NOTCH EXTENSIONS
Structure name: VINCENT AVE UC WIDEN ABUT 1L AND 2L PAVINF NOTCH EXTENSIONS
The fabricator/manufacturer/facility name: Holliday Rock
Material Information
The concrete mix design number: CT1-C2400
The truck number from where the sample was collected: 264
The batch plant ticket number from where the sample was collected: 101119199
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: PLANT
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: VINCENT AVE UC WIDEN ABUT 1L AND 2L PAVINF NOTCH EXTENSIONS
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 1
DIME Test ID: 2018-01-24-8-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/21/2018
Date Tested: 02/21/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.02 in
|
Average diameter of cylinder 2
|
6.01 in
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Compressive strength (to nearest 10 psi)
|
4950 psi
|
Maximum load on cylinder 1
|
142145 lb
|
Maximum load on cylinder 2
|
138910 lb
|
Compressive strength of cylinder 1
|
4994.6 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
4896.4 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data
|