Sample Record for 2018-02-01-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211070 DEA: 080Q3004 EFIS: 0800020191
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-138-R17.1/R19.2
Work Description: REALIGN SECTION OF STATE ROUTE 138
Location Description: Near Hesperia from 1.9 mi East of Route 15 to 0.1 mi West of Summit Post Office Road to realign sections of State Route 138
Contractor Name: Skanska Civil USA
Contractor Address: 1995 Agua Mansa Road, Riverside, CA 92509
Resident Engineer: Amgad Benjamin Structure Rep.: Tim Flores
Sample Information
DIME Sample ID: 2018-02-01-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Materials Management Branch Field Office
Sample Organization Contact: (562) 500-5861
Type of Sample: Authorization
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 02/01/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/05/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: No 5 Epoxy Rebar
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coating
Material Information
Rebar Heat Number(s): PL17210111
Rebar Epoxy Batch Number(s): TJ77002NA
Rebar Coating Specification: ASTM A775
Rebar Size (#): 5
Rebar Coating Color: Green
Rebar Manufacturer: Nucor
Rebar Coater: Western Coating
Rebar Powder Manufacturer: AkzoNobel Surface Chemistry, LLC
Release Number: Unknown
Quality Assurance Code: C172083
Test Results
Test 1 of 2
DIME Test ID: 2018-02-01-1-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 02/06/2018
Date Tested: 02/05/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
9.99
|
Second Bar Mean
|
9.14
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
12
|
Bar # for First Bar
|
no data
|
Bar # for Second Bar
|
no data
|
Total mean value
|
9.57
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
Test 2 of 2
DIME Test ID: 2018-02-01-1-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 02/06/2018
Date Tested: 02/05/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
2.6
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|