Print Report | Back to Sample Detail

Sample Record for 2018-01-30-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212745 DEA: 044G8004 EFIS: 0413000050 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-580-R26.8/R27.1
Work Description: BRIDGE DECK REHABILITATION
Location Description: ALAMEDA COUNTY, IN CASTRO VALLEY FROM 0.3 MILE WEST OF SUNNYSLOPE AVENUE OVERCROSSING TO 0.4 MILE EAST OF OLD DUBLIN ROAD
Contractor Name: MYERS AND SONS CONSTRUCTION, LP
Contractor Address: 4600 NORTHGATE BLVD, STE #100, SACRAMENTO, CA 95834
Resident Engineer: Lawrence Loi Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-01-30-4
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 01/30/2018
Date that the sample was received by the laboratory/organization performing the testing: 01/30/2018
The quantity of what the sample constitutes: 1 tanker
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik bond and Reichhold

Material Information

Mfg. Lot Number(s): 1099590
Batch number: 1099590
Mix number: 1099590

Test Results

Test 1 of 1

DIME Test ID: 2018-01-30-4-1
Test Method: CONCLP 3-16: Polyester Resin
Verified Date: 04/19/2018
Date Tested: 02/07/2018
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: polyester resin batch# 0001099590 is satisfactory for use (bond test, dog bone test and static volatile emissions test accepted suppliers test results)
Test Result Compliance:
Additional Comments When Verified:
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F 106
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35% 64.9
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi 3192
Styrene ASTM D 2369 40% to 50 % 47
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours 584
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams 0.2