Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 211669 DEA: 022C0904 EFIS: 0200000161
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-50.6/51.7
Work Description: BRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT
Location Description: PLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD
Contractor Name: MCM Construction
Contractor Address: 6413 32ND STREET, North Highlands, Ca 95660
Resident Engineer: Ronald Collins Structure Rep.: Jeffrey Rothgery
DIME Sample ID: 2018-01-11-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 01/11/2018
Date that the sample was received by the laboratory/organization performing the testing: 01/11/2018
The quantity of what the sample constitutes: 206
A brief description of the sample: A449 All thread
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS
Rocap Number(s): N/A
Heat Number(s): DL15105873
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: A449
Bolt Length(s): 16"
Nut Specification: N/A
Washer Specification: N/A
Finish: HDG
Diameter/Size: 3/4
Bolt Mfg. Lot Number: 29330
Rocap Test Requirement(s): No
Lubricant Requirements(s): No
DIME Test ID: 2018-01-11-2-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 01/22/2018
Date Tested: 01/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: 449 Althread Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1A | A449 .75 x 16 Althreaded Stud | 0.334 | 43860 | 195 | 131317 | 116059 | 38764 | 449 Althread Stud |
| |
UTM
|
400KIP
|
Temperature
|
72
|
DIME Test ID: 2018-01-11-2-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 01/22/2018
Date Tested: 01/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
DL15105873
|
Mfg. Lot Number
|
29330
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.75 in
|
Bolt Length
|
16 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-01-11-2-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 01/22/2018
Date Tested: 01/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
DL15105873
|
Mfg. Lot Number
|
29330
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.75 in
|
Bolt Length
|
16 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-01-11-2-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 01/22/2018
Date Tested: 01/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
DL15105873
|
Mfg. Lot Number
|
29330
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.75 in
|
Bolt Length
|
16 in
|
Gage Type
|
Pass
|
DIME Test ID: 2018-01-11-2-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/22/2018
Date Tested: 01/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
DL15105873
|
Mfg. Lot Number
|
29330
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.75 in
|
Bolt Length
|
16 in
|
Measurement Average
|
9.98 mils
|
DIME Test ID: 2018-01-11-2-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/22/2018
Date Tested: 01/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
DL15105873
|
Mfg. Lot Number
|
29330
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.75 in
|
Bolt Length
|
16 in
|
Measurement Average
|
8.96 mils
|
DIME Test ID: 2018-01-11-2-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/22/2018
Date Tested: 01/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
DL15105873
|
Mfg. Lot Number
|
29330
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.75 in
|
Bolt Length
|
16 in
|
Measurement Average
|
7.5 mils
|