Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2018-01-04-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 01/04/2018
Date that the sample was received by the laboratory/organization performing the testing: 01/04/2018
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Type II Cement
From where was the sample collected: Source
Laboratory sample identification: CM175761
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pan Pacific
DIME Test ID: 2018-01-04-2-2
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 01/18/2019
Date Tested: 01/12/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 Day Break -- Specimen 2 break was outside allowable range. Correct final result is 3250 PSI.
Test Result Compliance: complies
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
3260 psi
|
Compressive strength of 2nd specimen (psi)
|
2925 psi
|
Compressive strength of 3rd specimen (psi)
|
3247 psi
|
Average Compressive strength (to nearest 10 psi)
|
3140 psi
|
DIME Test ID: 2018-01-04-2-3
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 01/18/2019
Date Tested: 01/16/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
3974 psi
|
Compressive strength of 2nd specimen (psi)
|
4046 psi
|
Compressive strength of 3rd specimen (psi)
|
3784 psi
|
Average Compressive strength (to nearest 10 psi)
|
3930 psi
|
DIME Test ID: 2018-01-04-2-4
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 01/18/2019
Date Tested: 02/06/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 Day Break -- Specimen 3 break was outside allowable range. Correct final result is 5260 PSI.
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
5346 psi
|
Compressive strength of 2nd specimen (psi)
|
5171 psi
|
Compressive strength of 3rd specimen (psi)
|
4564 psi
|
Average Compressive strength (to nearest 10 psi)
|
5030 psi
|
DIME Test ID: 2018-01-04-2-5
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 01/18/2019
Date Tested: 01/11/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity
|
3.15
|
Water Content
|
240
|
The amount of flow (In percent)
|
89 %
|
The amount of water used (In percent)
|
68.6 %
|
Net Weight of Sample
|
843.1 grams
|
Air Content
|
6.3 %
|
DIME Test ID: 2018-01-04-2-6
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 01/18/2019
Date Tested: 01/24/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used
|
Type III grade reagent water
|
Time in minutes of last penetration greater than 25mm (E)
|
120 min
|
Time in minutes of first penetration less than 25mm (H)
|
135 min
|
Penetration reading at time E
|
33 mm
|
Penetration reading at time H
|
16 mm
|
Initial time of setting
|
127 min
|
Final time of setting
|
no data
|
Method Used
|
Test Method A
|
DIME Test ID: 2018-01-04-2-7
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 01/18/2019
Date Tested: 02/16/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used
|
Test Method A
|
Test Time
|
76 seconds
|
Fineness
|
3731 cm^2/g
|