Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2017-12-19-23
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 12/19/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/21/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: Coupon Castings
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SDI Farrar
Heat Number (s): K097, K157, K297, K307
Part Number (s): 196PC1BP 226AH ACS316SAH 226PCBP
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar Corporation
Prestressing Manufacturer: SDI
DIME Test ID: 2017-12-19-23-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 12/27/2017
Date Tested: 12/27/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
4
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | K297 | 0.504 | 0.1995 | 62692 | 108540 | 11.8 | Brian | | K307 | 0.503 | 0.1987 | 62365 | 107440 | 9.1 | Brian | | K097 | 0.502 | 0.1979 | 60935 | 105330 | 10.7 | Brian | | K157 | 0.503 | 0.1987 | 62789 | 108070 | 10.2 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|