Print Report | Back to Sample Detail

Sample Record for 2017-12-18-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 99999 DEA: 0322222 QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-12-18-9
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QAM Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7266
Type of Sample: Quality Control
Type of Material: Asphalt Modifier
Sample Taken Date: 12/18/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/18/2017
The quantity of what the sample constitutes: TEST
A brief description of the sample: Raffex 120
From where was the sample collected: Other
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refining Co Inc

Material Information

Asphalt Modifier Type: Raffex 120
Asphalt Modifier Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2017-12-18-9-1
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Verified Date: 12/18/2017
Date Tested: 12/18/2017
Submitted By Organization: CT HQ - QAM Sacramento Field Laboratory
Organization Address: 5900 Folsom Boulevard, MS 5,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brett.soldano@dot.ca.gov
Organization Phone: (562) 500-5861
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Ambient Barometric Pressure unit? kPa
Corrected Flash Point 216 C

Test 2 of 2

DIME Test ID: 2017-12-18-9-2
Test Method: ASTM D2007-11: Standard Test Method for Characteristic Groups in Rubber Extender and Processing Oils and Other Petroleum-Derived Oils by the Clay-Gel Absorption Chromatographic Method (Clay Gel Absorption)
Verified Date: 12/18/2017
Date Tested: 12/18/2017
Submitted By Organization: CT HQ - QAM Sacramento Field Laboratory
Organization Address: 5900 Folsom Boulevard, MS 5,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brett.soldano@dot.ca.gov
Organization Phone: (562) 500-5861
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method of determination of aromatic content: Desorption
Saturates, percent by mass 0.0 %
Polar compounds for 10 g sample 0.0 %
Polar compounds, mass % for 5 g sample 0.0 %
Asphaltenes, percent by mass 0.0 %
Aromatics, percent by mass 65.0 %