Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 7428 DEA: 07215944 EFIS: 0700001834
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-4.0/5.9
Work Description: RECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES.
Location Description: LOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Jerome Arabe Structure Rep.: Amare Tsegie
DIME Sample ID: 2017-12-07-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/07/2017
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 45 CY in Girder G2 6
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier: Bridge No 50 3060 Girder G2 6
Structure name: Sant Antonio Dr UC
The fabricator/manufacturer/facility name: OLDCASTLE PRECAST PERRIS
The concrete mix design number: UV-273
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: 57089
Concrete batch plant: Onsite
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Castind Bed B1
Where the material sample would have been placed if not sampled: Casting Bed B1 Girder G2 6
From Lot No.:
Bag Lot No.:
DIME Test ID: 2017-12-07-3-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 12/21/2017
Date Tested: 12/21/2017
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
5.99 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.18 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
8380 psi
|
Maximum load on cylinder 1
|
238900 lb
|
Maximum load on cylinder 2
|
234090 lb
|
Compressive strength of cylinder 1
|
8477.6 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
8280.5 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
14 days
|
Age of specimen in hours
|
no data
|