Print Report | Back to Sample Detail

Sample Record for 2017-10-26-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211507 DEA: 07279114 EFIS: 0715000075 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60-R24.4/R25.3
Work Description: CONSTRUCT RAMPS AND AUXILIARY LANE.
Location Description: LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM GRAND AVENUE OVERCROSSING TO 0.1 MILE WEST OF PROSPECTORS UNDERCROSSING
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 Cushing Suite 200, Irvine, CA 92618
Resident Engineer: Martin Sandoval Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-10-26-10
TL Number from the TL Form: 13257422
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/26/2017
Date that the sample was received by the laboratory/organization performing the testing: 11/13/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 958-22
Structure unique identifier: SIGN STRUCTURE OH 2 PILE FOUNDATION MEDIAN
Structure name: SIGN STRUCTURE OH 2 PILE FOUNDATION MEDIAN
The fabricator/manufacturer/facility name: ROBERTSONS

Material Information

The concrete mix design number: SM450R4R
The truck number from where the sample was collected: 1861
The batch plant ticket number from where the sample was collected: 13257422
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: SIGN STRUCTURE OH 2 PILE FOUNDATION MEDIAN
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2017-10-26-10-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/27/2017
Date Tested: 11/24/2017
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 6690 psi
Maximum load on cylinder 1 181235 lb
Maximum load on cylinder 2 196880 lb
Compressive strength of cylinder 1 6410.9 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 6964.3 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 29 days
Age of specimen in hours no data