Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044G4504 Cty SOL Rte 780 PM 7.07 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Jolie Schneider |
Date Reported: |
11/17/2017 |
|
Address: |
TL Number: |
20 |
||
City: |
||||
Project Name: REPLACE BRIDGE TO PROVIDE STANDARD VERTICAL CLEARANCE |
||||
Prime Contractor: R N R CONSTRUCTION, INC. |
||||
Sample Taken Date: |
10/20/2017 |
Mix Design: |
7337RSC |
|
Contractor: Unknown |
Location: LAUREL STREET OC |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.96 | 27.9 | 187837 | 6732.5 | 1 |
2 | 6.01 | 28.37 | 195174 | 6879.6 | 1 |
DIME Test ID: 2017-10-20-8-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6810
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
![]() |
TL- Report of Laboratory Testing