REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Garrett Griffith |
Date Reported: |
10/27/2017 |
|
Address: |
TL Number: |
Unknown |
||
City: |
||||
Project Name: ITS AND OPERATIONAL IMPROVEMENTS. |
||||
Prime Contractor: BALDWIN CONTRACTING COMPANY, INC. DBA KNIFE RIVER CONSTRUCT ION |
||||
Sample Taken Date: |
09/29/2017 |
Mix Design: |
000000000000 |
|
Contractor: Unknown |
Location: BUTTE AND SUTTER COUNTIES AT VARIOUS LOCATIONS |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.02 | 28.46 | 141102 | 4957.9 | 1 |
2 | 6.01 | 28.37 | 140323 | 4946.2 | 1 |
DIME Test ID: 2017-09-29-3-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4950
Age of specimen: 28 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |