Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2017-09-29-1
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 09/29/2017
Date that the sample was received by the laboratory/organization performing the testing: 10/03/2017
The quantity of what the sample constitutes: 12
A brief description of the sample: Wire Rope
From where was the sample collected: Other
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bridge Paint Crew
Reel Number: 63 1215
Painter Name or ID: 142210 139779 142195 142194 138696142283 142286 142193 135100 142284 142192 142704
Material Specification: ASTM A931
Size: 5/16 in
Wire Manufacturer: wire Rope
Material Collected to Test: Operator
DIME Test ID: 2017-09-29-1-1
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: 5/16 Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10877 lbf
|
Operator
|
Aris Fernadez
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-2
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10862 lbf
|
Operator
|
Aycan Nelper
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-3
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10932 lbf
|
Operator
|
Phittaya Vannasing
|
Location of Failure
|
Just Below Crimp
|
DIME Test ID: 2017-09-29-1-4
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10906 lbf
|
Operator
|
Amanda Chocker
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-5
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10893 lbf
|
Operator
|
Poberto Tucay
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-6
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10740 lbf
|
Operator
|
Edward Aquilar
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-7
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10928 lbf
|
Operator
|
Thomas Anuis
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-8
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10854 lbf
|
Operator
|
Justin Silva
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-9
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10907 lbf
|
Operator
|
Thomas Korycihsk
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-10
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10870 lbf
|
Operator
|
Chris Lyles
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-11
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 10/12/2017
Date Tested: 10/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10860 lbf
|
Operator
|
Joey Pascua Jr
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2017-09-29-1-12
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
Data has not been verified.