Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 101G4904 Cty AMA Rte 88 PM 54.0 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Colin Doran |
Date Reported: |
09/18/2017 |
|
Address: |
TL Number: |
173233 |
||
City: |
||||
Project Name: SALT STORAGE SHED BUILDING |
||||
Prime Contractor: BRM Construction |
||||
Sample Taken Date: |
09/11/2017 |
Mix Design: |
na |
|
Contractor: Unknown |
Location : IN AMADOR COUNTY AT THE PEDDLER HILL MAINTENANCE STATION |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.99 | 28.18 | 86177 | 3058.1 | 1 |
2 | 5.99 | 28.18 | 85398 | 3030.4 | 1 |
DIME Test ID: 2017-09-11-3-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3040
Age of specimen: 7 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing