Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 211800 DEA: 09356104 EFIS: 0912000044
QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-34.1
Work Description: CONSTRUCT MAINTENANCE EQUIPMENT STORAGE BUILDING AND SITE WORK.
Location Description: BUILDING CONSTRUCTION ADJACENT TO STATE HIGHWAY IN MONO COUNTY AT CRESTVIEW AT THE CRESTVIEW SATELLITE MAINTENANCE STATION
Contractor Name: ReCom Development Company
Contractor Address: 2488 Dixon Lane, Bishop, CA 93514
Resident Engineer: Joseph Blommer Structure Rep.: Alan Dever
DIME Sample ID: 2017-08-30-5
TL Number from the TL Form: C741434
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/30/2017
Date that the sample was received by the laboratory/organization performing the testing: 09/06/2017
The quantity of what the sample constitutes: 3
A brief description of the sample: Washers
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt
Rocap Number(s):
Heat Number(s): U9769
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: NA
Bolt Length(s): Unknown
Nut Specification: NA
Washer Specification: F436
Finish:
Diameter/Size: 1" Square Washer
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2017-08-30-5-1
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/11/2017
Date Tested: 09/08/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
U9769
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
PB
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.94 mils
|
DIME Test ID: 2017-08-30-5-2
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/11/2017
Date Tested: 09/08/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
U9769
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
PB
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.45 mils
|
DIME Test ID: 2017-08-30-5-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/11/2017
Date Tested: 09/08/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
U9769
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
PB
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.77 mils
|
DIME Test ID: 2017-08-30-5-4
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/11/2017
Date Tested: 09/08/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
U9769
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
PB
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
37.95
|
Spacing
|
Ok
|
DIME Test ID: 2017-08-30-5-5
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/11/2017
Date Tested: 09/08/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
U9769
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
PB
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.15
|
Spacing
|
Ok
|