Print Report | Back to Sample Detail

Sample Record for 2017-08-28-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211394 DEA: 100G8204 EFIS: 1013000073 QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-132-0.4/7.1
Work Description: REPAIR PAVEMENT AND INSTALL ITS ELEMENTS.
Location Description: SAN JOAQUIN COUNTY NEAR VERNALIS FROM 0.4 MILE EAST OF ROUTE 580 TO STANISLAUS COUNTY LINE
Contractor Name: BAY CITIES PAVING & GRADING, INC.
Contractor Address: 1450 Civic Ct. BLDG B #400, Concord CA, 94520
Resident Engineer: Wali Waziri Structure Rep.: Mohsen Abdelfatah

Sample Information

DIME Sample ID: 2017-08-28-4
TL Number from the TL Form: C925886
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 08/28/2017
Date that the sample was received by the laboratory/organization performing the testing: 08/29/2017
The quantity of what the sample constitutes: 1
A brief description of the sample: Epoxy Coated Dowel Basket
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dayton Superior

Material Information

Dowel Metal Heat Number: Na
Dowel Epoxy Batch Number: Unknown
Dowel Coating Specification: ASTM A884
Dowel Size: 1.25 in
Dowel Coating Color: Green
Dowel Manufacturer: Dayton Superior
Dowel Coater: Dayton Superior
Release Number: 1349571-2
Quality Assurance Code: Unknown
Rebar Size (#): Unknown

Test Results

Test 1 of 2

DIME Test ID: 2017-08-28-4-1
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 08/31/2017
Date Tested: 08/31/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 12.93 mils
Second Bar Mean 12.9 mils
Lower spec. limit LSL 7 mils
Upper spec. limit USL 40 mils
Total mean value 12.92 mils
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 2

DIME Test ID: 2017-08-28-4-2
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 08/31/2017
Date Tested: 08/31/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 3 ft
Holidays Per Linear Foot of Bar 0 holiday per ft
Holiday Test Pass/Fail Pass