Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210618 DEA: 06342534 EFIS: 0600000382 COOP: 061616A2
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-180-R74.1/R78.6
Work Description: CONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY
Location Description: FRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Justin Kimura Structure Rep.: Michael Trinh
DIME Sample ID: 2017-08-16-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 08/16/2017
Date that the sample was received by the laboratory/organization performing the testing: 08/21/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: 2 Ductile Iron Casting
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dywidag Systems
Heat Number (s): 2087
Part Number (s): 68 31 216 246
Material Specification: A536
Grades: 65-45-12
Metal Foundry Manufacturer (Mill): Golden Foundary Machine Co
Prestressing Manufacturer: Dywidag Systems
DIME Test ID: 2017-08-16-3-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 08/22/2017
Date Tested: 08/22/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
2
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 2067 | 0.497 | 0.194 | 44797 | 72360 | 20 | Fred | | 2067 | 0.497 | 0.194 | 44597 | 72000 | 20.2 | Fred |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|