REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Richard Duncan |
Date Reported: |
09/11/2017 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: |
||||
Prime Contractor: GHILOTTI BROS / RM HARRIS JV |
||||
Sample Taken Date: |
08/14/2017 |
Mix Design: |
4201a |
|
Contractor: Unknown |
Location : |
|||
Structure unique identifier: |
||||
Structure name: RW1 |
||||
Location of Pour: RW1 1354 to 1450 and 1546 to 1612 |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.37 | 6.01 | 5533.8 | 156994 | 1 |
2 | 28.37 | 6.01 | 5461.2 | 154934 | 1 |
DIME Test ID: 2017-08-14-2-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5500
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |