Sample Record for 2017-08-11-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210862 DEA: 031F4004 EFIS: 0300020420 QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-80-35.1/38.3
Work Description: WIDEN EASTBOUND ROADWAY
Location Description: WIDEN EASTBOUND ROADWAY
Contractor Name: A. TEICHERT & SON, INC. DBA TEICHERT CONSTRUCTION
Contractor Address: 400 Sunrise Ave. Ste. 300, Roseville, CA 95661
Resident Engineer: Phil Zink Structure Rep.: Carl Anderson

Sample Information

DIME Sample ID: 2017-08-11-9
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 594-1991
Type of Sample: Verification
Type of Material: Concrete Core
Sample Taken Date: 08/11/2017
Date that the sample was received by the laboratory/organization performing the testing: 08/14/2017
The quantity of what the sample constitutes: 3.70 cores
A brief description of the sample: cores
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: unk

Material Information

Detail description: pl17176
Structure names: pl1717
Type of material: concrete

Test Results

Test 1 of 1

DIME Test ID: 2017-08-11-9-1
Test Method: ASTM C42-13: Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete
Verified Date: 08/18/2017
Date Tested: 08/15/2017
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: 295+45
Test Result Compliance:
Additional Comments When Verified:
Length of Core 5.95 in
L/D Ratio 1.63
Diameter of Core 3.65 in
Type of Fracture 1
Age of Specimen 50 days
Compressive Strength 5740 psi
Correction Factor 0.97
Corrected Strength 5570 psi
Calculated Density 0 lb/ft^3