Sample Record for 2017-08-04-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211669 DEA: 022C0904 EFIS: 0200000161
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-50.6/51.7
Work Description: BRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT
Location Description: PLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD
Contractor Name: MCM Construction
Contractor Address: 6413 32ND STREET, North Highlands, Ca 95660
Resident Engineer: Ronald Collins Structure Rep.: Jeffrey Rothgery
Sample Information
DIME Sample ID: 2017-08-04-1
TL Number from the TL Form: C939701
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 08/04/2017
Date that the sample was received by the laboratory/organization performing the testing: 08/08/2017
The quantity of what the sample constitutes: 101 of 4 foot bars
A brief description of the sample: 1 inch all-thread bar
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Eng
Material Information
Production or Authorization Testing: Authorization Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type: Deformed
Rebar Size: 1"
Nut Specification for Threaded Bar: A29
System Manufacturer: Eaton Steel
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 62139078
Nut Heat Number(s): NF15203286, 396574
Bar Lot Number: Unknown
Nut Lot Number: 26F1D, 26D5D
Coupler Heat Number(s): N/A
Coupler Grade: N/A
Test Results
Test 1 of 6
DIME Test ID: 2017-08-04-1-1
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/09/2017
Date Tested: 08/09/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 1 | A722 1\" Threaded Bar & Nut | L96-126-17 | 0.85 | 146386 | 119192 | 4.4 | 0 | A722 Threaded Bar and Nut | Brian |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|
Test 2 of 6
DIME Test ID: 2017-08-04-1-2
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/09/2017
Date Tested: 08/09/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke Outside Reduced Area
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 2 | A722 1\" Threaded Bar & Nut | L96-126-17 | 0.771 | 150485 | 122586 | 0 | 0 | Bar Broke Outside Reduced Area | Brian |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|
Test 3 of 6
DIME Test ID: 2017-08-04-1-3
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/09/2017
Date Tested: 08/09/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 3 | A722 1\" Threaded Bar & Nut | L96-126-17 | 0.748 | 167664 | 140141 | 0 | 37.6 | A722 Threaded Bar and Nut | Brian |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|
Test 4 of 6
DIME Test ID: 2017-08-04-1-4
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/09/2017
Date Tested: 08/09/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 4 | A722 1\" Threaded Bar & Nut | L96-126-17 | 0.85 | 145786 | 118800 | 0 | 0 | A722 Threaded Bar and Nut | Brian |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|
Test 5 of 6
DIME Test ID: 2017-08-04-1-5
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
Data has not been verified.
Test 6 of 6
DIME Test ID: 2017-08-04-1-6
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
Data has not been verified.