Print Report | Back to Sample Detail

Sample Record for 2017-08-01-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211238 DEA: 080R4404 EFIS: 0812000093 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R23.0/R36.2
Work Description: INSTALL VEGETATION CONTROL UNDERNEATH EXISTING METAL BEAM GUARD RAIL
Location Description: INSTALL VEGETATION CONTROL UNDERNEATH EXISTING METAL BEAM GUARD RAIL
Contractor Name: Dreambuilder Construction Corporation
Contractor Address: 1324 Lawson Ln, Placentia, CA 92870
Resident Engineer: Denise Sostrom Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-08-01-11
TL Number from the TL Form: 001
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/01/2017
Date that the sample was received by the laboratory/organization performing the testing: 08/03/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 964-01
Structure unique identifier: RT SHOULDER
Structure name: Unknown
The fabricator/manufacturer/facility name: ROBERTSONS

Material Information

The concrete mix design number: NP
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: NP
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2017-08-01-11-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/29/2017
Date Tested: 08/29/2017
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 4
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.02 in
Average diameter of cylinder 3 6.00 in
Average diameter of cylinder 4 5.99 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.46 in^2
Cross sectional area of cylinder 3 28.27 in^2
Cross sectional area of cylinder 4 28.18 in^2
Compressive strength (to nearest 10 psi) 1270 psi
Maximum load on cylinder 1 36490 lb
Maximum load on cylinder 2 36400 lb
Maximum load on cylinder 3 35760 lb
Maximum load on cylinder 4 35060 lb
Compressive strength of cylinder 1 1282.2 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 1279.0 psi
Compressive strength of cylinder 3 1264.9 psi
Compressive strength of cylinder 4 1244.1 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Type of fracture pattern of cylinder 4 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Correction factor for cylinder 3 no data
Correction factor for cylinder 4 no data
Age of specimen 28 days
Age of specimen in hours no data