Project Information

Project ID: 211238 DEA: 080R4404 EFIS: 0812000093 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R23.0/R36.2
Work Description: INSTALL VEGETATION CONTROL UNDERNEATH EXISTING METAL BEAM GUARD RAIL
Location Description: INSTALL VEGETATION CONTROL UNDERNEATH EXISTING METAL BEAM GUARD RAIL
Contractor Name: Dreambuilder Construction Corporation
Contractor Address: 1324 Lawson Ln, Placentia, CA 92870
Resident Engineer: Denise Sostrom Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-08-01-11
TL Number from the TL Form: 001
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/01/2017
Date that the sample was received by the laboratory/organization performing the testing: 08/03/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 964-01
Structure unique identifier: RT SHOULDER
Structure name: Unknown
The fabricator/manufacturer/facility name: ROBERTSONS

Material Information

The concrete mix design number: NP
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: NP
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2017-08-01-11-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/29/2017
Date Tested: 08/29/2017
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 4
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.02 in
Average diameter of cylinder 3 6.00 in
Average diameter of cylinder 4 5.99 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.46 in^2
Cross sectional area of cylinder 3 28.27 in^2
Cross sectional area of cylinder 4 28.18 in^2
Compressive strength (to nearest 10 psi) 1270 psi
Maximum load on cylinder 1 36490 lb
Maximum load on cylinder 2 36400 lb
Maximum load on cylinder 3 35760 lb
Maximum load on cylinder 4 35060 lb
Compressive strength of cylinder 1 1282.2 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 1279.0 psi
Compressive strength of cylinder 3 1264.9 psi
Compressive strength of cylinder 4 1244.1 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Type of fracture pattern of cylinder 4 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Correction factor for cylinder 3 no data
Correction factor for cylinder 4 no data
Age of specimen 28 days
Age of specimen in hours no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.