Print Report | Back to Sample Detail

Sample Record for 2017-07-27-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212572 DEA: 030G9404 EFIS: 0317000204 QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-5,50-
Work Description: Remove MLS and 1" polyester concrete overlay on Pioneer Bridge in Sacramento, CA.
Location Description: Sacramento, CA
Contractor Name: MYERS AND SONS CONSTRUCTION LP
Contractor Address: 600 NORTHGATE BLVD., STE 100, SACRAMENTO, CA 95834
Resident Engineer: JEFF HAMM Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-07-27-9
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: 760-518-6064
Type of Sample: Quality Control
Type of Material: Methacrylate
Sample Taken Date: 07/27/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/27/2017
The quantity of what the sample constitutes: 25000 gal
A brief description of the sample: 2 pints 204,chp,zcure,8020
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: kwik Bond, Benecia

Material Information

Mfg. Lot Number(s): 1770389488
Batch number: 1770389488
Mix number: 1770389488

Test Results

Test 1 of 1

DIME Test ID: 2017-07-27-9-1
Test Method: CONCLP 4-16: HMWM
Verified Date: 10/06/2017
Date Tested: 10/06/2017
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F 20 cps
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F 1.09
Volatile content (ASTM D 2369) 30% max 24 %
Flash point (ASTM D 3828) more than 180 deg F 220 F
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours 595 psi
Tack free time, 400 minutes max 280 minutes

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.