Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044G4504 Cty SOL Rte 780 PM 7.07 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Jolie Schneider |
Date Reported: |
08/02/2017 |
|
Address: |
TL Number: |
6 |
||
City: |
||||
Project Name: REPLACE BRIDGE TO PROVIDE STANDARD VERTICAL CLEARANCE |
||||
Prime Contractor: R N R CONSTRUCTION, INC. |
||||
Sample Taken Date: |
07/26/2017 |
Mix Design: |
ct063C |
|
Contractor: Unknown |
Location : LAUREL STREET OC |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.02 | 28.46 | 82915 | 2913.4 | 1 |
2 | 6.02 | 28.46 | 70834 | 2488.9 | 1 |
DIME Test ID: 2017-07-26-8-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 2700
Age of specimen: 7 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
![]() |
TL- Report of Laboratory Testing