Sample Record for 2017-07-03-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 210874 DEA: 07287104 EFIS: 0700020899
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10,101-S0.0/S0.1,0.0/0.1
Work Description: CONSTRUCT CONCRETE BARRIER.
Location Description: LA COUNTY IN LA FROM SOUTHBOUND ROUTE 101 TO EASTBOUND ROUTE 10 CONNECTOR AND WESTBOUND ROUTE 10 TONORTHBOUND ROUTE 101
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 1792 KAISER AVENUE, IRVINE, CA 92614
Resident Engineer: PRAVIN PATEL Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2017-07-03-3
TL Number from the TL Form: S1
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/03/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/24/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 962-S1
Structure unique identifier: Unknown
Structure name: BARRIER RAIL
The fabricator/manufacturer/facility name: ASSOCIATE READY MIX
Material Information
The concrete mix design number: 557237
The truck number from where the sample was collected: 365
The batch plant ticket number from where the sample was collected: 5690450
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: truck
Where the material sample would have been placed if not sampled: COLOR TYPE 60 C MOD
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 1
DIME Test ID: 2017-07-03-3-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/31/2017
Date Tested: 07/31/2017
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.03 in
|
Average diameter of cylinder 2
|
6.02 in
|
Cross sectional area of cylinder 1
|
28.56 in^2
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
Compressive strength (to nearest 10 psi)
|
6200 psi
|
Maximum load on cylinder 1
|
173290 lb
|
Maximum load on cylinder 2
|
180470 lb
|
Compressive strength of cylinder 1
|
6067.6 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
6341.2 psi
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data
|