Print Report | Back to Sample Detail

Sample Record for 2017-07-18-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 7428 DEA: 07215944 EFIS: 0700001834 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-4.0/5.9
Work Description: RECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES.
Location Description: LOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Jerome Arabe Structure Rep.: Amare Tsegie

Sample Information

DIME Sample ID: 2017-07-18-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 07/18/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/18/2017
The quantity of what the sample constitutes: 3
A brief description of the sample: 0.6 Steel PT Strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific National Transport

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s): 6181
Number of Coils: 1
Group Number: Unknown
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): 1204764
Mfg. Lot Number(s): 201209PSM00020
Manufacturer(s): Kiswire

Test Results

Test 1 of 2

DIME Test ID: 2017-07-18-2-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 08/02/2017
Date Tested: 08/01/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
120476461810.222605925307827.11.88Brian
UTM 120KIP
Temperature 72 F
Extensometers E88766

Test 2 of 2

DIME Test ID: 2017-07-18-2-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 08/02/2017
Date Tested: 08/01/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
120476461810.2226004352856271.79Brian
UTM 120KIP
Temperature 72 F
Extensometers E88766