Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2017-07-07-10
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/07/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/10/2017
The quantity of what the sample constitutes: 5
A brief description of the sample: A325 Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hodell-Natco Fontana
Rocap Number(s): NA
Heat Number(s): NA
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: A325
Bolt Length(s): 1.750
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: .750
Bolt Mfg. Lot Number: Fontana
Rocap Test Requirement(s):
Lubricant Requirements(s): NA
DIME Test ID: 2017-07-07-10-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2017-07-07-10-5
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2017-07-07-10-6
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2017-07-07-10-7
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2017-07-07-10-8
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2017-07-07-10-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
4.29 mils
|
DIME Test ID: 2017-07-07-10-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
3.94 mils
|
DIME Test ID: 2017-07-07-10-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
5.13 mils
|
DIME Test ID: 2017-07-07-10-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
3.32 mils
|
DIME Test ID: 2017-07-07-10-13
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
2.97 mils
|
DIME Test ID: 2017-07-07-10-14
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
31.57
|
Spacing
|
Ok
|
DIME Test ID: 2017-07-07-10-15
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
32.07
|
Spacing
|
Ok
|
DIME Test ID: 2017-07-07-10-16
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/12/2017
Date Tested: 07/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
780561
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
1.75 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
32.7
|
Spacing
|
Ok
|