Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2017-07-10-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Proficiency
Type of Material: Cementitious
Sample Taken Date: 07/10/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/10/2017
The quantity of what the sample constitutes: 1 box
A brief description of the sample: CCRL 206
From where was the sample collected: Fabricator
Laboratory sample identification: CM178206
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCRL
DIME Test ID: 2017-07-10-2-2
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/22/2019
Date Tested: 07/14/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
3546 psi
|
Compressive strength of 2nd specimen (psi)
|
3553 psi
|
Compressive strength of 3rd specimen (psi)
|
3428 psi
|
Average Compressive strength (to nearest 10 psi)
|
3510 psi
|
DIME Test ID: 2017-07-10-2-3
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/22/2019
Date Tested: 07/18/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
4231 psi
|
Compressive strength of 2nd specimen (psi)
|
4302 psi
|
Compressive strength of 3rd specimen (psi)
|
4123 psi
|
Average Compressive strength (to nearest 10 psi)
|
4220 psi
|
DIME Test ID: 2017-07-10-2-4
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/22/2019
Date Tested: 08/08/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
5521 psi
|
Compressive strength of 2nd specimen (psi)
|
4971 psi
|
Compressive strength of 3rd specimen (psi)
|
5295 psi
|
Average Compressive strength (to nearest 10 psi)
|
5260 psi
|
DIME Test ID: 2017-07-10-2-5
Test Method: ASTM C151-15: Standard Test Method for Autoclave Expansion of Hydraulic Cement
Verified Date: 03/22/2019
Date Tested: 08/02/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Change in length of specimen(In percent)
|
0.106 %
|
DIME Test ID: 2017-07-10-2-6
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 03/22/2019
Date Tested: 07/20/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity
|
3.15
|
Water Content
|
236
|
The amount of flow (In percent)
|
90 %
|
The amount of water used (In percent)
|
67.4 %
|
Net Weight of Sample
|
826.7 grams
|
Air Content
|
8.9 %
|
DIME Test ID: 2017-07-10-2-7
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Verified Date: 03/22/2019
Date Tested: 07/13/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Mass of Water
|
168 g
|
Mass of Dry Cement
|
650 g
|
Water required for normal consistency
|
25.8 %
|
DIME Test ID: 2017-07-10-2-9
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 03/22/2019
Date Tested: 07/13/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used
|
Type IV grade reagent water
|
Initial time of setting
|
150 min
|
Final time of setting
|
240 min
|
DIME Test ID: 2017-07-10-2-10
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 03/22/2019
Date Tested: 07/28/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used
|
Test Method A
|
Test Time
|
89 seconds
|
Fineness
|
4025 cm^2/g
|
DIME Test ID: 2017-07-10-2-11
Test Method: ASTM C266-15: Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
Verified Date: 03/22/2019
Date Tested: 07/13/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial time of setting
|
160 min
|
Final time of setting
|
220 min
|
DIME Test ID: 2017-07-10-2-12
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 03/22/2019
Date Tested: 07/26/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Corrected residue, % (Rc)
|
3.16 %
|
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325)
|
96.84 %
|
DIME Test ID: 2017-07-10-2-13
Test Method: ASTM C451-13: Standard Test Method for Early Stiffening of Hydraulic Cement (Paste Method)
Verified Date: 03/22/2019
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent final penetration
|
73 %
|
DIME Test ID: 2017-07-10-2-14
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Verified Date: 03/22/2019
Date Tested: 08/02/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specimen A Initial measurement at 24 hours
|
0.271 in
|
Specimen B Initial measurement at 24 hours
|
0.2404 in
|
Specimen C Initial measurement at 24 hours
|
0.2674 in
|
Specimen D Initial measurement at 24 hours
|
0.2837 in
|
Specimen A Final measurement at 14 days
|
0.2712 in
|
Specimen B Final measurement at 14 days
|
0.2404 in
|
Specimen C Final measurement at 14 days
|
0.2676 in
|
Specimen D Final measurement at 14 days
|
0.2839 in
|
The average length of change of the four specimens
|
0.015 %
|