Sample Record for 2017-07-06-9
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211800 DEA: 09356104 EFIS: 0912000044
QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-34.1
Work Description: CONSTRUCT MAINTENANCE EQUIPMENT STORAGE BUILDING AND SITE WORK.
Location Description: BUILDING CONSTRUCTION ADJACENT TO STATE HIGHWAY IN MONO COUNTY AT CRESTVIEW AT THE CRESTVIEW SATELLITE MAINTENANCE STATION
Contractor Name: ReCom Development Company
Contractor Address: 2488 Dixon Lane, Bishop, CA 93514
Resident Engineer: Joseph Blommer Structure Rep.: Alan Dever
Sample Information
DIME Sample ID: 2017-07-06-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/06/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/13/2017
The quantity of what the sample constitutes: 1 Lot of 40
A brief description of the sample: F1554 anchor rods
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt
Material Information
Rocap Number(s): N/A
Heat Number(s): PL17200423
Nut Mfg. Lot Number(s): 75064846
Washer Mfg. Lot Number(s): 0716-292
Bolt Specification: F1554, Gr 36
Bolt Length(s): 12"
Nut Specification: A563 DH
Washer Specification: A436-1
Finish: HDG
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: PL1720042352
Rocap Test Requirement(s): None
Lubricant Requirements(s): Yes
Test Results
Test 1 of 10
DIME Test ID: 2017-07-06-9-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 07/20/2017
Date Tested: 07/18/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: F1554 Gr 36
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1A | F1554 Gr 36 | 0.226 | 14319 | 63 | 63358 | 55225 | 12481 | F1554 Gr 36 |
| |
UTM
|
400KIP
|
Temperature
|
72
|
Test 2 of 10
DIME Test ID: 2017-07-06-9-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
PL17200423
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BLUE PAINT
|
Size
|
.625 in
|
Bolt Length
|
12 in
|
Gage Type
|
Pass
|
Test 3 of 10
DIME Test ID: 2017-07-06-9-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
PL17200423
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BLUE PAINT
|
Size
|
.625 in
|
Bolt Length
|
12 in
|
Measurement Average
|
5.49 mils
|
Test 4 of 10
DIME Test ID: 2017-07-06-9-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0716-292
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
TSI F436
|
Size
|
.625 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.53 mils
|
Test 5 of 10
DIME Test ID: 2017-07-06-9-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0716-292
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
TSI F436
|
Size
|
.625 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.81 mils
|
Test 6 of 10
DIME Test ID: 2017-07-06-9-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0716-292
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
TSI F436
|
Size
|
.625 in
|
Bolt Length
|
no data in
|
Measurement Average
|
6.93 mils
|
Test 7 of 10
DIME Test ID: 2017-07-06-9-7
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0716-292
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
TSI F436
|
Size
|
.625 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.8
|
Spacing
|
Ok
|
Test 8 of 10
DIME Test ID: 2017-07-06-9-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/20/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0716-292
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
TSI F436
|
Size
|
.625 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
38.25
|
Spacing
|
Ok
|
Test 9 of 10
DIME Test ID: 2017-07-06-9-9
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 07/20/2017
Date Tested: 07/20/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: F1554 Gr 36
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1B | F1554 Gr 36 | 0.226 | 18241 | 81 | 80712 | 54662 | 12354 | F1554 Gr 36 |
| |
UTM
|
400KIP
|
Temperature
|
72
|
Test 10 of 10
DIME Test ID: 2017-07-06-9-10
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 07/20/2017
Date Tested: 07/20/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: F1554 Gr 36
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1C | F1554 Gr 36 | 0.226 | 18234 | 81 | 80681 | 55109 | 12455 | F1554 Gr 36 |
| |
UTM
|
400KIP
|
Temperature
|
72
|