Sample Record for 2017-07-06-6
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211800 DEA: 09356104 EFIS: 0912000044
QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-34.1
Work Description: CONSTRUCT MAINTENANCE EQUIPMENT STORAGE BUILDING AND SITE WORK.
Location Description: BUILDING CONSTRUCTION ADJACENT TO STATE HIGHWAY IN MONO COUNTY AT CRESTVIEW AT THE CRESTVIEW SATELLITE MAINTENANCE STATION
Contractor Name: ReCom Development Company
Contractor Address: 2488 Dixon Lane, Bishop, CA 93514
Resident Engineer: Joseph Blommer Structure Rep.: Alan Dever
Sample Information
DIME Sample ID: 2017-07-06-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/06/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/13/2017
The quantity of what the sample constitutes: 1 Lot of 16
A brief description of the sample: F1554 anchor bolt
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt
Material Information
Rocap Number(s): N/A
Heat Number(s): 2051398
Nut Mfg. Lot Number(s): 75064846
Washer Mfg. Lot Number(s): N/A
Bolt Specification: F1554, Gr 36
Bolt Length(s): 12"
Nut Specification: A563 DH
Washer Specification: N/A Building work
Finish: HDG
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: N/A
Rocap Test Requirement(s): None
Lubricant Requirements(s): Yes
Test Results
Test 1 of 4
DIME Test ID: 2017-07-06-6-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 07/19/2017
Date Tested: 07/18/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: F1554 Gr 36
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1A | F1554 Gr 36 Bolt | 0.226 | 18363 | 81 | 81252 | 59442 | 13434 | F1554 Gr 36 |
| |
UTM
|
400KIP
|
Temperature
|
72
|
Test 2 of 4
DIME Test ID: 2017-07-06-6-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 07/19/2017
Date Tested: 07/18/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: F1554 Gr 36
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1B | F1554 Gr 36 Bolt | 0.226 | 18258 | 81 | 80788 | 60943 | 13773 | F1554 Gr 36 |
| |
UTM
|
400KIP
|
Temperature
|
72
|
Test 3 of 4
DIME Test ID: 2017-07-06-6-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/19/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
2051398
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
PB 307A
|
Size
|
.625 in
|
Bolt Length
|
12 in
|
Gage Type
|
Pass
|
Test 4 of 4
DIME Test ID: 2017-07-06-6-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/19/2017
Date Tested: 07/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
2051398
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
PB 307A
|
Size
|
.625 in
|
Bolt Length
|
12 in
|
Measurement Average
|