Print Report | Back to Sample Detail

Sample Record for 2017-06-30-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210735 DEA: 071193U4 EFIS: 0713000007 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-37.2/42.4
Work Description: CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location Description: IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
Contractor Name: Guy F. Atkinson
Contractor Address: 18201 Von Karman Ave, Suite #800, IRVINE CA 92612
Resident Engineer: Rodolfo Cao Structure Rep.: David Win

Sample Information

DIME Sample ID: 2017-06-30-7
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 06/30/2017
Date that the sample was received by the laboratory/organization performing the testing: 07/05/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: DSI Threaded Bar
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI Gerdau Farrar

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: 10
Nut Specification for Threaded Bar: A897
System Manufacturer: DSI
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 6214211502
Nut Heat Number(s): A307
Bar Lot Number: NA
Nut Lot Number: NA
Coupler Heat Number(s): NA
Coupler Grade: NA

Test Results

Test 1 of 2

DIME Test ID: 2017-06-30-7-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/07/2017
Date Tested: 07/06/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar & Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1#10 Bar Heat #6214211502, Nut Heat #A307L02050171.271123287651817.2A615 Bar & NutFred
Temperature 72 F
UTM 400KIP

Test 2 of 2

DIME Test ID: 2017-06-30-7-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/07/2017
Date Tested: 07/06/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar & Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
2#10 Bar Heat #6214211502, Nut Heat #A307L02050171.27112076764040A615 Bar & NutFred
Temperature 72 F
UTM 400KIP